Measurement repetitions value selection

You can use number series formulas to select which measurement from repeat measurements appears on the report.

If you want to use measurement repetitions and decide which of the measurements appears on the report, you can use formulas for numerical series. The individual measured values of the measurement repetition are to be treated as a numerical series. To do this, first create at least 2 columns in the corresponding parameter (Add Parameter). One column for the measurement results and one for the result that should appear on the report (this must be selected in the report table editor).

In the column for the result, you store a formula that selects which of the values should be chosen. For this, you use the formulas from Calculating with number sequences.

For example, you can store the following formulas (with 2 columns, column 0 contains the final result):

Highest measured value max(this(1))
Lowest measured value min(this(1))
First measured value first(this(1))
Last measured value last(this(1))
2nd measured value csventry(1, this(1))
Average of all repetitions mittelwert(this(1))

This is how it could look if you always took the highest value:

Last change: 25.08.2025

Allgemeines

Einführungsphase

Auswertungen

Mitarbeiter

Aufträge

Proben

Probenvorlage

Berichte

Kunden

Berichtstabellen Editor

Kundenzone (optional)

Anlagen

Angebote

Rechnungen

Parameter

Rechnen mit Parametern

Schnittstellen

Webservice

Transformationscode

Prüfpläne / Grenzwerte / Spezifikationen

Dokumentenlenkung

Fragen und Antworten

Prüfmittel

Material

Mitarbeiterschulungen

8D-Report

Sonstiges

PDF-Vorlagen

Lieferantenbewertung

Dateiverwaltung

Prozesse